Commit 45d3bcdf authored by luz's avatar luz

DALI: make sure overload protector is reset at beginning

parent b9298651
......@@ -97,7 +97,7 @@ bool DaliComm::isBusy()
// - 3 byte debug commands
#define CMD_CODE_ECHO_DATA1 0x41 // returns RESP_DATA echoing DATA1
#define CMD_CODE_ECHO_DATA2 0x42 // returns RESP_DATA echoing DATA2
#define CMD_CODE_OVLRESET 0x43 // reset overload, DATA1 0=autoreset enabled, 1=autoreset disabled
#define CMD_CODE_OVLRESET 0x43 // reset overload, DATA1 0=autoreset enabled, 1=autoreset disabled, 0x55=overload detector disabled
#define CMD_CODE_EDGEADJ 0x44 // set DALI sending edge adjustment, DATA1=sending delay for going-inactive edge, DATA2=delay of sampling point, in number of 1/256th periods (with actual resolution of 1/16th bit for now)
// bridge responses
......@@ -301,6 +301,8 @@ void DaliComm::reset(DaliCommandStatusCB aStatusCB)
sendBridgeCommand(CMD_CODE_RESET, 0, 0, NULL);
sendBridgeCommand(CMD_CODE_RESET, 0, 0, NULL);
sendBridgeCommand(CMD_CODE_RESET, 0, 0, NULL);
// make sure bus overload protection is active, autoreset enabled, reset to operating
sendBridgeCommand(CMD_CODE_OVLRESET, 0, 0, NULL);
// set DALI signal edge adjustments (available from fim_dali v3 onwards)
sendBridgeCommand(CMD_CODE_EDGEADJ, sendEdgeAdj, samplePointAdj, NULL);
// terminate any special commands on the DALI bus
......